Micromod Micro-DCI: 53MT6000 Micro-Tools Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Software Micromod Micro-DCI: 53MT6000 Micro-Tools. Micromod Micro-DCI: 53MT6000 Micro-Tools User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL MICRO-DCI®53MT6000Micro-Tools™PN26002 Rev.1

Página 2 - MicroMod Automation, Inc

53MT6000 INSTRUCTION MANUALviii ContentsFigure 6-6. Create a New Project, Method 3 ... 31Fig

Página 3 - TABLE OF CONTENTS

53MT6000 INSTRUCTION MANUAL84 Database EditorCommunications Mode - Digital:This parameter selects whether discrete (digital) values are being

Página 4 - 7.0 - DATABASE EDITOR

53MT6000 INSTRUCTION MANUALDatabase Editor 85Watchdog Time 16-31(Digital):This parameter is used to specify the watchdog condition. Assuming a

Página 5

53MT6000 INSTRUCTION MANUAL86 Database EditorSamples to Average: This parameter is used to specify the number of 100 ms samples to be taken fo

Página 6 - 10.0 - THE DOCUMENTER

53MT6000 INSTRUCTION MANUALDatabase Editor 877.4.16.3 Modbus Master Parameter ConfigurationOnce the preferred PLC device has been selected, a se

Página 7 - 12.0 - SUPPORT SERVICES

53MT6000 INSTRUCTION MANUAL88 Database EditorSet UP: This designates the data format transfer protocol. Clicking on the "down arrow"

Página 8 - LIST OF FIGURES

53MT6000 INSTRUCTION MANUALDatabase Editor 89There are restrictions on the maximum number of L & C type data that can be read. Refer to the

Página 9

53MT6000 INSTRUCTION MANUAL90 Database EditorThere are restrictions on the maximum number of L & C type data that can be written. Refer t

Página 10

53MT6000 INSTRUCTION MANUALDatabase Editor 917.4.16.4 Modbus Slave Parameter ConfigurationOnce the preferred PLC device has been selected, a sep

Página 11 - LIST OF TABLES

53MT6000 INSTRUCTION MANUAL92 Database EditorSet Up Error: This index number refers to a problem with the read or write setup parameters [DDI

Página 12

53MT6000 INSTRUCTION MANUALDatabase Editor 937.4.16.5 Siemens Parameter ConfigurationOnce the preferred PLC device has been selected, a separate

Página 13 - SAFETY SUMMARY

53MT6000 INSTRUCTION MANUALContents ixFigure 7-34. Printer Parameter Configuration Window ...103Figure 7-35. Pas

Página 14

53MT6000 INSTRUCTION MANUAL94 Database EditorThere are restrictions on the maximum number of L & C type data that can be read. Refer to t

Página 15 - READ FIRST

53MT6000 INSTRUCTION MANUALDatabase Editor 95There are restrictions on the maximum number of L & C type data that can be written. Refer to

Página 16

53MT6000 INSTRUCTION MANUAL96 Database EditorWrite Command Code:This selection is used to tell the PLC the type of write to perform. There ar

Página 17 - 1.0 INTRODUCTION

53MT6000 INSTRUCTION MANUALDatabase Editor 977.4.16.6 Koyo Parameter ConfigurationOnce the preferred PLC device has been selected, a separate co

Página 18 - 1.3 Model Number Breakdown

53MT6000 INSTRUCTION MANUAL98 Database EditorSet UP: This designates the data format transfer protocol. Clicking on the "down arrow"

Página 19 - 2.0 REQUIREMENTS

53MT6000 INSTRUCTION MANUALDatabase Editor 99There are restrictions on the maximum number of L & C type data that can be written. Refer to

Página 20 - 4 Requirements

53MT6000 INSTRUCTION MANUAL100 Database EditorMemory Type: This selection is used to tell the PLC the type of write to perform. This type must

Página 21 - 3.0 INSTALLATION

53MT6000 INSTRUCTION MANUALDatabase Editor 1017.4.16.7 HART Parameter ConfigurationThis DDI interface selection is for use with the HART multi-d

Página 22 - 3.3 Hardware Installation

53MT6000 INSTRUCTION MANUAL102 Database EditorENTRYEXPLANATIONMode: This displayed value represents the index number of the PLC type. [DDIA =

Página 23

53MT6000 INSTRUCTION MANUALDatabase Editor 1037.4.16.8 Printer Parameter ConfigurationWhen configured to the printer interface mode, the DDI por

Página 24

53MT6000 INSTRUCTION MANUALx Contents

Página 25

53MT6000 INSTRUCTION MANUAL104 Database Editor7.4.17 PASSWORDS MenuThis option is only viewable when configuring a 53MC5000 on-line. To view a

Página 26

53MT6000 INSTRUCTION MANUALDatabase Editor 1057.4.18 CALIBRATION MenuThis option, illustrated in Figure 7-36, is only viewable when configuring

Página 27 - Installat ion 11

53MT6000 INSTRUCTION MANUAL106 Database Editor

Página 28 - (ID-53-1610)

53MT6000 INSTRUCTION MANUALF-TRAN Programming 1078.0 F-TRAN PROGRAMMINGThe F-TRAN Editor accessed using the button on the Project Toolbar provi

Página 29 - (ID-53-1597)

53MT6000 INSTRUCTION MANUAL108 F-TRAN Programming8.3 Editing an F-TRAN FileOnce an F-TRAN file has been selected the F-TRAN EDITOR window open

Página 30 - 3.4.1 Pre-Setup Procedure

53MT6000 INSTRUCTION MANUALF-TRAN Programming 1098.6 Assigning the Function IndexEach instance of Control, Display or Subroutine F-TRAN programs

Página 31

53MT6000 INSTRUCTION MANUAL110 F-TRAN Programming8.7.1 How to Initiate the Image BuildClick on the F-TRAN Image Builder button in the Projec

Página 32

53MT6000 INSTRUCTION MANUALGraphical Configuration 1119.0 GRAPHICAL CONFIGURATION9.1 IntroductionThe 53MC5000 Controller supports two types of F

Página 33 - 3.4.10 New Program Folder

53MT6000 INSTRUCTION MANUAL112 Graphical Configuration 9.5 Creating a New FCS or F-CIM ApplicationNew FCS and F-CIM Applications can be create

Página 34

53MT6000 INSTRUCTION MANUALGraphical Configuration 1139.6 Softwiring Through Graphics9.6.1 Introduction to STGSoftwiring Through Graphics (STG)

Página 35 - 4.0 START-UP

53MT6000 INSTRUCTION MANUALviii Safety SummarySAFETY SUMMARY ∆ GENERALWARNINGSPOSSIBLE PROCESS UPSETSMaintenance must be performed only by qua

Página 36

53MT6000 INSTRUCTION MANUAL114 Graphical Configuration9.6.3 The Application Editor9.6.3.1 Opening the EditorAn existing FCS or F-CIM applicati

Página 37 - 5.2 The Micro-Tools Window

53MT6000 INSTRUCTION MANUALGraphical Configuration 115To add free-form graphics to a diagram:1. Choose one of the graphic tools on the STG appli

Página 38

53MT6000 INSTRUCTION MANUAL116 Graphical Configuration9.6.4.3 Zooming/PanningIf you want to keep a popup open for zooming and panning, choose

Página 39 - 5.3 Toolbars

53MT6000 INSTRUCTION MANUALGraphical Configuration 1179.6.5.1 Notes WindowUser notes can be attached to a function block file. Simply enter you

Página 40 - 5.4 Status Bar

53MT6000 INSTRUCTION MANUAL118 Graphical Configuration

Página 41 - 5.6 Accessing On-Line Help

53MT6000 INSTRUCTION MANUALThe Documenter 11910.0 THE DOCUMENTER10.1 OverviewThe Micro-Tools Documenter provides a flexible method of defining p

Página 42

53MT6000 INSTRUCTION MANUAL120 The Documenter10.2.5 OKYou can add and remove templates from this list in the report editing dialog that appear

Página 43

53MT6000 INSTRUCTION MANUALTroubleshooting 12111.0 TROUBLESHOOTING11.1 General RecommendationsMicro-Tools is primarily a software product which

Página 44 - 6.1 Project Manager Window

53MT6000 INSTRUCTION MANUAL122 Troubleshooting• That DAO 3.5 is loaded properly (refer to Section 3.4.6).• That Services are active.• That Lic

Página 45

53MT6000 INSTRUCTION MANUALSupport Services 12312.0 SUPPORT SERVICESA number of support services are available to users of the 53MT6000 and othe

Página 46

53MT6000 INSTRUCTION MANUALix Safety Summary

Página 47 - 6.2 How to Create a Project

53MT6000 INSTRUCTION MANUAL124 Support Services12.3 Replacement PartsThe 53MT6000 is a software product. Optional hardware items available for

Página 48

53MT6000 INSTRUCTION MANUALSupport Services 125When ordering standard parts for the 53MT6000, use the part numbers and descriptions shown in Tab

Página 49

53MT6000 INSTRUCTION MANUAL126 Support Services

Página 51

The Company’s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice, or

Página 52 - 6.4.2 Exporting

53MT6000 INSTRUCTION MANUALRead First ixREAD FIRSTContacting MicroMod Automation Inc.Should assistance be required with any MicroMod Automation

Página 53 - 6.5 Project Variables

53MT6000 INSTRUCTION MANUALx Read First

Página 54

53MT6000 INSTRUCTION MANUALIntroduction 11.0 INTRODUCTION1.1 OverviewMicro-Tools™ is a Windows®-based configuration tool for the 53MC5000 family

Página 55 - 7.0 DATABASE EDITOR

53MT6000 INSTRUCTION MANUAL2 Introduction1.3 Model Number BreakdownRefer to the MicroMod data sheet or data tag for the model number of the pr

Página 56 - ∆ WARNING:

53MT6000 INSTRUCTION MANUALR e q u i r e m e n ts 3 2.0 REQUIREMENTS2.1 Hardware Requirements 2.1.1 Minimum Hardware RequirementsThe fo

Página 57

MicroMod Automation, Inc.The CompanyMicroMod Automation is dedicated to improving customer efficiency by providing the most ost-effective, application

Página 58

53MT6000 INSTRUCTION MANUAL4 Requirements

Página 59 - ❢ CAUTION

53MT6000 INSTRUCTION MANUALInstallati on 5 3.0 INSTALLATIONMicro-Tools is composed of several hardware and software components integrated in

Página 60

53MT6000 INSTRUCTION MANUAL6 Installationon this icon. The screen should appear as shown in Figure 3-1.• From the drop-down menu that appears,

Página 61 - 7.4 Sub-Menu Descriptions

53MT6000 INSTRUCTION MANUALInstallati on 7 ing a parallel device to be attached to it. If a device (for example, a printer) is already conne

Página 62 - 7.4.2 ANO Menu

53MT6000 INSTRUCTION MANUAL8 Installation3.3.2.1 Connecting to a Single 53MC5000 ControllerTo connect a computer COM port on the computer to a

Página 63 - 7.4.3 CCI Menu

53MT6000 INSTRUCTION MANUALInstallati on 9 4. Connect the Instrument DataLink cable to the TOP connector at the rear of the SUPERVISOR-PC ca

Página 64 - 7.4.4 CCO Menu

53MT6000 INSTRUCTION MANUAL10 Installation3. The bare wire end of the 677B907 cable can be connected to the first controller's standard r

Página 65 - 7.4.5 Menu

53MT6000 INSTRUCTION MANUALInstallat ion 11 Figure 3-5. Connecting the Computer’s COM Port to the DataLink

Página 66

53MT6000 INSTRUCTION MANUAL12 InstallationFigure 3-6. Micro-Tools DataLink SUPERVISOR Card to DataLink Interconnection Diagram(ID-53-1610)

Página 67

53MT6000 INSTRUCTION MANUALInstallation 13 Figure 3-7. Micro-Tools MicroLink SUPERVISOR Card to MicroLink Interconnection Diagram(ID-53-1597

Página 68

53MT6000 INSTRUCTION MANUALContents iTABLE OF CONTENTSSAFETY SUMMARY... viiiREAD

Página 69

53MT6000 INSTRUCTION MANUAL14 Installation3.4 Installing the Micro-Tools SoftwareNow the process of installing the Micro-Tools software can be

Página 70

53MT6000 INSTRUCTION MANUALInstallation 15 3.4.5 Micro-DCI Communication Services Location•The Choose Destination Location window appears, w

Página 71

53MT6000 INSTRUCTION MANUAL16 Installation3.4.8 Adding Micro-DCI NetworksIf you would like to add Micro-DCI instrument networks, click on the

Página 72

53MT6000 INSTRUCTION MANUALInstallation 17 • If you clicked the Browse button, enter both the drive and directory you want to use as the des

Página 73

53MT6000 INSTRUCTION MANUAL18 Installation• Repeat the above steps for each license key.• When finished, select Exit from the File menu.• At t

Página 74

53MT6000 INSTRUCTION MANUALStart-up 194.0 START-UP4.1 Micro-Tools StartupWhen 53MT6000 Setup is complete, the following Windows Menu Group is cr

Página 75

53MT6000 INSTRUCTION MANUAL20 Start-upThe function of the icons contained in the Micro-DCI Communications Services Menu Group are detailed bel

Página 76

53MT6000 INSTRUCTION MANUAL Overview of User Interface 215.0 OVERVIEW OF USER INTERFACEBecause the Micro-Tools software runs under the Microsoft

Página 77

53MT6000 INSTRUCTION MANUAL22 Overview of User InterfaceFigure 5-1. Micro-Tools Windowproject toolbarapplication toolbarmenu bartitle bar with

Página 78

53MT6000 INSTRUCTION MANUAL Overview of User Interface 235.3 Toolbars5.3.1 Project ToolbarProject Selector Specify the default project to be con

Página 79

53MT6000 INSTRUCTION MANUALii Contents3.4.9 Selecting the Target Location for the Micro-Tools System ...163.4.10 New Program Folder

Página 80 - 7.4.8 PARAMETER Menu

53MT6000 INSTRUCTION MANUAL24 Overview of User Interface5.3.2 Application ToolbarThe tools available on the Application Toolbar will vary with

Página 81 - 7.4.9 SDT Menu

53MT6000 INSTRUCTION MANUAL Overview of User Interface 25 5.6 Accessing On-Line HelpMany windows, such as pop-ups, provide a HELP button to acce

Página 82

53MT6000 INSTRUCTION MANUAL26 Overview of User Interface

Página 83 - 7.4.10 TOTALIZER Menu

53MT6000 INSTRUCTION MANUAL Micro-Tools Project Manager 276.0 THE MICRO-TOOLS PROJECT MANAGERThe Micro-Tools package is designed to be used to c

Página 84

53MT6000 INSTRUCTION MANUAL28 Micro-Tools Project Manager6.1 Project Manager WindowThe Micro-Tools PROJECT MANAGER window provides a hierarchi

Página 85 - 7.4.11 TREND Menu

53MT6000 INSTRUCTION MANUAL Micro-Tools Project Manager 29The Library folder contains all the standard control strategies for FCS (Flexible Cont

Página 86

53MT6000 INSTRUCTION MANUAL30 Micro-Tools Project Managerthe controller folder should match the controller’s tagname (each controller has a us

Página 87 - 7.4.12 EXTERNAL Menu

53MT6000 INSTRUCTION MANUAL Micro-Tools Project Manager 316.2 How to Create a ProjectUse one of the following methods to access the dialog box u

Página 88

53MT6000 INSTRUCTION MANUAL32 Micro-Tools Project Manager6.3 Project Backup and RestoreThe complete project database can be backed up to anoth

Página 89 - 7.4.13 COMMUNICATION Menu

53MT6000 INSTRUCTION MANUAL Micro-Tools Project Manager 333. Choose a path and filename for the backup file. The file extension .MTB will be add

Página 90

53MT6000 INSTRUCTION MANUALContents iii7.2.1 Specifying an Off-Line Instrument Database in a Project...397.2.2 Selecting an On-Line

Página 91 - 7.4.14 DATA TABLES Menu

53MT6000 INSTRUCTION MANUAL34 Micro-Tools Project Manager6.4 Importing and Exporting Project Configuration Data6.4.1 ImportingSeveral methods

Página 92 - 7.4.15 OPTIONS Menu

53MT6000 INSTRUCTION MANUAL Micro-Tools Project Manager 356.4.1.3 Importing the F-TRAN Image OnlyIn some situations, source-file F-TRAN files ar

Página 93 - 7.4.16 DDI Menu

53MT6000 INSTRUCTION MANUAL36 Micro-Tools Project Manager6.4.1.4 Importing the Controller’s DatabaseA hex file representation of a controller’

Página 94

53MT6000 INSTRUCTION MANUAL Micro-Tools Project Manager 376.5 Project VariablesYou can assign project-wide values to variables used in the Micro

Página 95

53MT6000 INSTRUCTION MANUAL38 Micro-Tools Project Manager

Página 96

53MT6000 INSTRUCTION MANUALDatabase Editor 397.0 DATABASE EDITORThe Micro-Tools Database Editor provides a menu oriented configuration tool for

Página 97 - 00 = successful - no error

53MT6000 INSTRUCTION MANUAL40 Database Editor7.2.2 Selecting an On-Line 53MC5000 to ConfigureThere are two ways to access a database for On-Li

Página 98

53MT6000 INSTRUCTION MANUALDatabase Editor 41One of the buttons on the right of the window is used to access the Data Tables. The Data Tables a

Página 99

53MT6000 INSTRUCTION MANUAL42 Database Editortrends continue to update.• Execute a Flexible Control Strategy (FCS) (B000 = 1):The process con

Página 100

53MT6000 INSTRUCTION MANUALDatabase Editor 43• Execute the custom F-CIM sequence (B000 = 99): The user can configure the controller to perform

Página 101

53MT6000 INSTRUCTION MANUALiv Contents8.0 - F-TRAN PROGRAMMING8.1 F-TRAN File Storage ...

Página 102

53MT6000 INSTRUCTION MANUAL44 Database Editor7.3.3 Making Changes to a Module’s ConfigurationWhen a module is selected from the main window, t

Página 103

53MT6000 INSTRUCTION MANUALDatabase Editor 457.4 Sub-Menu DescriptionsThe following sections describe the module windows displayed when each ite

Página 104

53MT6000 INSTRUCTION MANUAL46 Database Editor7.4.2 ANO MenuThe number of analog outputs per controller is dependent on the options purchased w

Página 105

53MT6000 INSTRUCTION MANUALDatabase Editor 477.4.3 CCI MenuThe number of discrete (contact) inputs per controller is dependent on the options pu

Página 106

53MT6000 INSTRUCTION MANUAL48 Database Editor7.4.4 CCO MenuThe number of discrete (contact) outputs per controller is dependent on the options

Página 107

53MT6000 INSTRUCTION MANUALDatabase Editor 497.4.5 MenuThe button for the SYSTEM menu is at the right of the Database Editor window. The SYSTEM

Página 108

53MT6000 INSTRUCTION MANUAL50 Database EditorThe window for the SYSTEM module contains the entries listed below:ENTRYEXPLANATIONUnit Tagname:

Página 109

53MT6000 INSTRUCTION MANUALDatabase Editor 51Scan Index: This selection determines the execution rate of the control program. This is an index

Página 110

53MT6000 INSTRUCTION MANUAL52 Database EditorDay: Run Time Counter or Real Time Clock (53MC5000B only). This value in conjunction with secon

Página 111

53MT6000 INSTRUCTION MANUALDatabase Editor 537.4.6 Display List ConfigurationClicking on the DISPLAY button at the right side of the Database Ed

Página 112

53MT6000 INSTRUCTION MANUALContents v10.2.1 Database... 11910.2

Página 113

53MT6000 INSTRUCTION MANUAL54 Database EditorThe number of control modules per Controller is dependent on the options purchased with the Contr

Página 114

53MT6000 INSTRUCTION MANUALDatabase Editor 557.4.7.2 OUTPUT Configurable ParametersThe control module OUTPUT parameters may be configured by cli

Página 115

53MT6000 INSTRUCTION MANUAL56 Database EditorENTRYEXPLANATIONTagname: Tagname of the CON module [A00].Output Track Status:Displays the current

Página 116

53MT6000 INSTRUCTION MANUALDatabase Editor 577.4.7.3 SETPOINT Configurable ParametersThe control module SETPOINT parameters may be configured by

Página 117 - Database Editor 101

53MT6000 INSTRUCTION MANUAL58 Database EditorSP Track Enable: This parameter is used in conjunction with the Setpoint Track Switch to select t

Página 118

53MT6000 INSTRUCTION MANUALDatabase Editor 597.4.7.4 ALARM Configurable ParametersThe control module ALARM parameters can be configured by click

Página 119

53MT6000 INSTRUCTION MANUAL60 Database Editor7.4.7.5 TUNING Configurable ParametersThe control module TUNING parameters may be configured by c

Página 120 - 7.4.17 PASSWORDS Menu

53MT6000 INSTRUCTION MANUALDatabase Editor 617.4.7.6 TREND Configurable ParametersThe control module TREND parameters can be configured by click

Página 121 - 7.4.18 CALIBRATION Menu

53MT6000 INSTRUCTION MANUAL62 Database Editor7.4.7.7 STATUS Configurable ParametersThe control module STATUS parameters may be configured by c

Página 122 - 106 Database Editor

53MT6000 INSTRUCTION MANUALDatabase Editor 63Control Alarm Ack: This database parameter is used to acknowledge the control module alarms.Control

Página 123 - 8.0 F-TRAN PROGRAMMING

53MT6000 INSTRUCTION MANUALvi ContentsLIST OF FIGURESFigure 3-1. My Computer Icon and Menu...

Página 124 - 8.3 Editing an F-TRAN File

53MT6000 INSTRUCTION MANUAL64 Database Editor7.4.8 PARAMETER Menu There are eight PARAMETER modules available in the 53MC5000. Parameter modul

Página 125 - 8.7 Building An F-TRAN Image

53MT6000 INSTRUCTION MANUALDatabase Editor 657.4.9 SDT Menu There are two STATUS DISPLAY (SDT) Modules available in the 53MC5000. Each SDT modul

Página 126

53MT6000 INSTRUCTION MANUAL66 Database EditorRead Only: Entering a 1 prevents an operator from changing the state of points via controller fro

Página 127 - 9.0 GRAPHICAL CONFIGURATION

53MT6000 INSTRUCTION MANUALDatabase Editor 677.4.10 TOTALIZER Menu There are eight Totalizer modules that can be configured. The TOT module para

Página 128 - 9.5.2 Starting from Scratch

53MT6000 INSTRUCTION MANUAL68 Database EditorScaling: This parameter is used for scaling and time interval integration. The totalizer input i

Página 129 - 9.6.1 Introduction to STG

53MT6000 INSTRUCTION MANUALDatabase Editor 697.4.11 TREND Menu Eight TREND modules are available in a Modular Controller. The window for each T

Página 130 - 9.6.3 The Application Editor

53MT6000 INSTRUCTION MANUAL70 Database EditorTrend Height: Height of the trend at full scale, measured in "display dots".Trend Zero:

Página 131 - 9.6.4 Component Editor

53MT6000 INSTRUCTION MANUALDatabase Editor 717.4.12 EXTERNAL Menu One EXTERNAL INPUT module is available on each 53MC5000 Controller. This featu

Página 132 - 9.6.5 Border Editor

53MT6000 INSTRUCTION MANUAL72 Database Editor The following example will read C50 from instrument 15 every 3 seconds and store the value in lo

Página 133

53MT6000 INSTRUCTION MANUALDatabase Editor 737.4.13 COMMUNICATION MenuIt is possible to change communication parameters using this sub-menu. IF

Página 134

53MT6000 INSTRUCTION MANUALContents viiFigure 7-16. Status Parameter Configuration Window ...62Figure 7-17. P

Página 135 - 10.0 THE DOCUMENTER

53MT6000 INSTRUCTION MANUAL74 Database EditorNote that none of these parameters affect the configuration port on the 53MC5000 Controller front

Página 136 - 10.5 Printing a Report

53MT6000 INSTRUCTION MANUALDatabase Editor 757.4.14 DATA TABLES Menu If you are already very familiar with the structure of the 53MC5000 databas

Página 137 - 11.0 TROUBLESHOOTING

53MT6000 INSTRUCTION MANUAL76 Database Editor7.4.15 OPTIONS Menu The Options configuration window (Figure 7-24) allows the configuration of th

Página 138

53MT6000 INSTRUCTION MANUALDatabase Editor 777.4.16 DDI MenuTwo Digital Device Interfaces (DDI-A and DDI-B) are available as options in the 53MC

Página 139 - 12.0 SUPPORT SERVICES

53MT6000 INSTRUCTION MANUAL78 Database Editor7.4.16.1 Allen Bradley Parameter ConfigurationOnce the preferred PLC device has been selected, a

Página 140 - 12.3 Replacement Parts

53MT6000 INSTRUCTION MANUALDatabase Editor 79Set UP: This designates the data format transfer protocol. Clicking on the "down arrow"

Página 141 - 12.4 Technical Documentation

53MT6000 INSTRUCTION MANUAL80 Database EditorThere are restrictions on the maximum number of L & C type data that can be read. Refer to t

Página 142 - 126 Support Services

53MT6000 INSTRUCTION MANUALDatabase Editor 81There are restrictions on the maximum number of L & C type data that can be written. Refer to

Página 143

53MT6000 INSTRUCTION MANUAL82 Database Editor7.4.16.2 OPTO 22 Parameter ConfigurationOnce the preferred PLC device has been selected, a separa

Página 144

53MT6000 INSTRUCTION MANUALDatabase Editor 83Set UP: This designates the data format transfer protocol. Clicking on the "down arrow"

Comentários a estes Manuais

Sem comentários