Micromod MOD: Modcell 2050R Quick Reference Guide Manual do Utilizador Página 2

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 2
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 1
operator accesses 12 menus through the setup keys
summarized in the chart on the reverse side. For
Moves through the basic
Scroll:
Advancestostepl. * BRD CALIBRAT
Enters a YES response. ARE YOU SURE? YES, NO
(
If YES, all confi
g
ura- or SKIP LOCKOUT RAT BIAS TYPE RATIO, BIAS, RAT BIAS SEG 1 SOAK TIM XXX.
X
(
0 to 3000.0 hours o
r
Down: • Moves down through tion data is written over with TOTALIZE DI1 FUNC RUN/STOP, RUN/RSET, RATIO SOURCE LOCAL, REMOTE minutes)
menus. factory default values) RUN/HOLD
(
See IB-23C650
)
BIAS SOURCE LOCAL, REMOTE SEG 1 RMP RATE XXX.
X
(
Chan
g
e
p
er unit time in
Decreases values. CONFIG CHANGED For information only R/H, RSET LOCKOUT YES, NO
(
See IB-23C650 fo
r
RATIO BALANCE STANDARD
(
Ma
y
bum
p
when en
ineerin
units
Enters a NO response. SOFTWARE VERSION For information only or RESET LOCKOUT ex
p
lanation
)
switchin
g
manual to auto
)
, SEG 1 RELAY A ON, OFF
DISPLAY VERSION For information only or RUN/HOLD LOCKOU
T
AUTO
(
Bum
p
less Transfer
)
SEG 1 RELAY B ON, OFF
Top/Middle Display Bottom Display/Entry R/L KEY LOCKOUT YES, NO Not valid if source is remote. SEG 1 RELAY C ON, OFF
BASE CFG **MENU** INPUTS **NENU* LOC-REM ALLOWED NO, YES BIAS BALANCE Same entries as Ratio SEG 1 GUARANTD NO, YES
MAIN PWR FREQ 60 HERTZ, 50 HERTZ DECIMAL POINT 0., 0.0, 0.00, 0.000 DIG IN 1 ACTION REVERSE, DIRECT Balance SEG 2 SETUP Entry point for Segment 2.
PROC INP TYPE MILLIAMP
(
0 to 54 mA dc
)
, PROC INP SETUP Entr
y
p
oint for in
p
ut setu
p
DIGITAL INPUT 2 Entr
y
p
oint for Di
g
ital In
p
ut 1. RATIO SOURCE LOCAL, REMOTE. For ratio and Same ste
p
s as for Se
g
ment 1.
VOLT
(
0 to 6V dc
)
, PRC TEMP UNITS CELSIUS, FAHRENHT Same ste
p
s as Di
g
ital In
p
u 1. Bias t
yp
e. Onl
y
one remote Re
p
eat for Se
g
ments 3-10.
THERMCPL
(
Thermocou
p
le
)
, PROC INP MA. HI
X
X. XX
(
1.00 to 54.00 mA dc
)
, DI SETPT SEL LIST
(
15 combinations available, source allowed.
RTD
(
RTD In
p
ut
)
, or MV. HI XX. X
(
0 to 120 mV dc
)
, see IB-23C650 for listin
g)
BIAS SOURCE LOCAL, REMOTE. For ratio and TOTALIZE **MENU*
*
MILLIVLT
(
-10 to 120 mV dc
)
or VOLTS. HI X.XX
(
0.00 to 5.OOV dc
)
Bias t
yp
e. Onl
y
one remote WRAP AT PRED CNT NO
(
Counts until turned off or
SLIDEWIR
(
0 to 100% slide- PROC HI POSITION - X .XXX
(
0.000 to 1.000
)
MA. OUTP **NENU
*
source allowed. max. count reached
)
,
wire wiper position) PROC INP MA. LO OUTPUT MA. HIGH XX.X
(
01.0 to 54.0 mA dc
)
RATIO BALANCE For Ratio and Bias t
yp
e. Same YES
(
Counts to
p
redetermine
d
PROC INP IC TYPE TYPE *
(
J, K, E, R, 5, T, B, N
)
o
r
MV. LO XX. XX
(
0.00 to 53.00 mA do
)
. OUTPUT MA. LOW XX.X
(
0 to mA Hi
g
h less 1 mA dc
)
entries as Ratio Balance. count & wra
p
s to
p
reset value
)
PROCESS TEMP CAL Entry point tor temperature or VOLTS LO XX.X
(
-10.0 to llOmVdc
)
. HEAT OUT HI LIMIT XX.
X
(
0.1 to 110.00/0 of heat BIAS BALANCE For Ratio and Bias t
yp
e. Same INPUT THRSHOLD XXX
X
(
0 to En
g
ineerin
g
Unit
s
correction PROC LO POSITION XXX (0.00 to 4.90 V dc) output span) entries as Ratio Balance. High Value, in eng. units)
PR TEMP= XXX.X XX.
X
(
XXX.X = Process tem- XXXX
(
0.000 to 0.900
)
COOL OUT HI LIMIT XX.X
(
0.1 tO 110.0% of cool TOTALIZE IS OFF For information onl
y
perature, XX.X = Temperature PROCESS LIN TYPE NONE, SQR ROOT output span) SETPTS **MENU** or IS ON
correction [+15 to -15]) PROC ENG UNITS HI XXXX (-3000 to 30000) OUTPUT HI LIMIT XX.X
(
10.0 to 110% of mA LOC SETP Entr
y
p
oint for set-
p
oint setu
p
TOTALIZE DIRECT UP, DOWN
INPUT 2 ENABLE NO, YES PROC ENG UNITS LO XXXX (-3000 to 30000) output span, 10.0 to 100% of LOC SETP FIXED NO, YES TOTALIZE RATE PER SEC, PER MIN, PER HOUR
INPUT 2 TYPE Same steps as Input1 type PR FAULT OUTPUT - XX (0 to 100%) relay output span) LOC SETP HI LIMIT XXXX (Low limit to 30000) SCALE DEC PT 0., 0.0, 0.00, 0.000
PR FAULT LEVL PCI XX (0 to 100%). See OUTPUT LO LIMIT XX.X
(
-8% or 0% rela
y
to LOC SETP LO LIMIT XXXX
(
-3000 to hi
g
h limit
)
SCALE FACTOR XXX
X
(
0.001 TO 30000
)
OUTPUT TYPE CUR PROP
(
Current
p
ro
p
.
)
, IB-23C650 for limits hi
g
h limit less 1.0%
)
LOC SETP INIT VAL XXX X
(
Low limit to hi
g
h limit
)
PRESET VALUE XXXXXX
X
(
.000 to 9999999
)
POS PROP
(
Position
p
ro
p
.
)
, RECOVERY OPTION MANUAL, LAST LIMIT IN MANUAL NO, YES=Limits a
pp
l
y
in Manual SETPT 2 Entr
y
p
oint for set-
p
oint 2 FREDETRD COUN
T
XXXXXX
X
(
.000 to 9999999
)
HC/R
R
(
Heat/Coo/, dual rela
y)
, POWER UP OUTP SRC LAST, FIXED SETPT 2 ENABLE NO, YES
HC/CR
(
HeatiCool, mA/rela
y)
, INPUT 2 SETUP Same ste
p
s as Process In
p
ut1 FIXED PWR UP OUTPT
X
X.X
(
-8.0 to 110.0, within Out- ALARMS **MENU*
*
HC/CC
(
Heat/Cool, dual mA
)
, Setu
p
thru En
g
. Units Low
p
ut hi
g
h and low limits
)
SETPT 2 FIXED Same ste
p
s as Set-
p
oint 1 BEEP ON OCCUR OF NONE, or an
y
combination of:
ON/OFF
(
On,Off
)
, I2 FAULT ACTION NONE, LOCAL
(
Controller
p
ut in Fixed thru Initial Value. DG, P1, P2
TIM PROP
(
Time
p
ro
p
ort.
)
auto mode with fault value
)
RETRANS VARIABLE PROCESS, SETPOINT, Re
p
eat for Set-
p
oints 3 and 4 ALARM ACK REQD ON NONE, or an
y
combination of:
POS PROP has position choice NONE
(
Fix out
p
ut 2 at 0 mA
)
POWER UP SETP SRC LAST, LOC SETPT. SETPT 2, DG, P1, P2
CONTROL ACTION DIRECT, REVERSE I2 FAULT VALUE XXXX (-3000 to 30000) RETRANS PROC HI XXX
X
(
-3000 to 30000
)
Decima
l
SETPT 3, SETPT 4, REM SETP OVERCFGD DIAG ON YES , NO
MA. OUTP ACTION DIRECT, REVERSE I2 FAULT LEVL PCI XX (0 to 100%) or SETPT HI placed per "Inputs" Menu. INPUT 2 MISSING Warning message. times out in P1 RELAY ACTION LATCHING
(
rela
y
release
s
HEAT OUT ACTION DIRECT, REVERSE RETRANS PROC LO XXX
X
(
-3000 to 30000
)
Decma
l
1 second. when alarm acknowled
g
ed
)
,
COOL OUT ACTION DIRECT, REVERSE ENG UNIT LABEL XXXX
(
X=an
y
character in Ta
g
or SETPT LO
p
laced
p
er "In
p
uts" Menu. FIXD PWR UP SETPT XXXX
(
-3000 to 30000, within NO LATCH
(
rela
y
release
s
VALVE CALIB See IB-23C650. Name field in Tune menu) local set-point limits) when alarm condition not
HOLD PWR UP MSG NO, YES
(
Hold ‘POWE
R
RIGHT BAR OUTPUT
(
Out
p
ut dis
p
la
y
ed
)
OUTPUT 2 MA. HIGH XX. X
(
01.0 to 54.0 mA dc
)
SETPOINT TRACKING NO, YES
(
Note: Remote se
t
p
resent
)
FAILED’ message at startup) DEVIATN
(
Deviation dis
p
la
y
ed
)
OUTPUT 2 MA. LOW XX. X
(
0 to 53.0 m
A
p
oint cannot track
)
POWER UP MODE LAST, AUTO, MANUAL 0EV BAR FULL SCL XX
(
1 to 100% of s
p
an
)
DISPLAYS AND ENTRIES Top/Middle Display Bottom Display/Entry Top/Middle Display Bottom Display/Entry Top/Middle Display Bottom Display/Entry Top/Middle Display Bottom Display/Entry
RAT BIAS ENABLE NO, YES DIG INPT **MENU** RELAYS **MENU** RAMPSOAK **MENU*
The MODCELL 2050 generates display prompts to AUTOTUNE ENABLE NO, YES DIGITAL INPUT 1 Entry point for Digital Input 1. RELAY A SETUP Entry point for Relay A setup RAMPSOAK REPEAT NO, YES
make setup and operation fast and easy. The RAMPSOAK ENABLE NO, YES DIG IN 1 FUNCTION NONE, AUTO/MAN, ALRM ACK, RELAY A FUNCTION NONE, ALARMS, TOTALIZE, SOAK HYST XXX
X
(
0 to 30000
)
TOTALIZE ENABLE NO, YES TOTALIZE, RAMPSOAK, RAMPSOAK, REM/LOC, RAMP HYST XXX
X
(
0 to 30000
)
described below. The sequence of menus is RS-485 ENABLE YES, NO SETP SEL AUTO/MAN RAMPSOAK IS OFF For information only
TUNE PASSWORD XXXX (Enter this value [0 to DIG A-M OUT ENAB NO, YES RELAY A TRIP ACT On alarm
s
1, 2, 3, 4, 12, 13 o
r
IS ON
more detailed information, see IB-23C650. 30000] in ‘Displays’ menu) DIG A-M OUT VAL XX.
X
(
0 TO 54.0 mA
)
14, 23, 24, 34, 123, 124, 134, RAMPSOAK UNIT TIM MINUTES, HOURS
CONFIG PASSWORD XXX
X
(
Enter this value
[
0 to A/M KEY LOCKOUT YES, NO 234, 1234 RAMPSOAK SEGMENTS XX
(
0 to 10
)
30000] in Displays menu) MAN-AUTO ALLOWED NO, YES RELAY B SETUP Same steps as Relay A Setup. SEG 1 SETUP Entry point for Segment 1
setup steps. CHK SUM DATABASE YES (ARE YOU SURE?), NO RAMPSOAK DI1 FUNC RUN/STOP, RUN/HOLD, RELAY C SETUP Same steps as Relay A Setup. SEG 1 START SP XXXX
(
Local Set-
p
oint Low Limit
See IB-23C650. RUN/SKIP
(
See IB-23C650
)
to Local Set-
p
oint Hi
g
h Limit
)
Up: • Moves up through menus. DEFAULT DATABASE Up key requests default R/H, RSET LOCKOUT YES, NO
(
See IB-23C650 fo
r
RS-485 **MENU* See IB-23C650M SEG 1 END SP
X
XXX
(
Local Set-
p
oint Low Limit
Increases values. LOCK CFG MENUS NO=Reaci access, YES or RUN/HOLD LOCKOU
T
ex
p
lanation. RAT BIAS **MENU*
*
to Local Set-
p
oint Hi
g
h Limit
)
Vista de página 1
1 2